Pump type toxic and harmful gas detector

HC-503 pump type toxic and harmful gas detector is used for portable rapid detection of toxic and harmful gas concentration, temperature and humidity measurement and alarm. The concentration is displayed on 2.5-inch HD color screen in real time, and the gas sensor is selected from imported brands (Honeywell, Japan Root, UK CITY, UK Alpha, UK Dynament, Switzerland Membrapor, etc.). The main detection principles are: electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photoion. Advanced circuit design, mature kernel algorithm processing, has obtained a number of software patents and appearance patents. MS600 can detect the concentration of gas in the pipeline or confined space, atmospheric environment, can detect gas leakage or a variety of background gas nitrogen or oxygen high concentration of single gas purity, detection of more than 500 types of gas.

Product type: Pump type toxic and harmful gas detector

Sampling method: pump type

Gas type: combustible gas, oxygen, carbon monoxide, ammonia (optional)

Detection principle: electrochemical principle

Measuring range: 0-100%LEL, 0-25%vol, 0-100ppm, 0-100ppm

Resolution: 0.01%

Response time: ≤30S (T90)

Detection error: ≤±3%FS or ±10% (depending on the specific sensor)

Alarm mode: 95 dB (@30cm) alarm tone, high alarm, low alarm, TWA,STEL multiple alarm types sound, light, vibration alarm, high and low alarm value can be set by the host computer or calibration platform

Battery life: more than 2 years under normal use, no need to charge, the battery can be replaced

Explosion-proof grade: Ex ia IIC T4 Ga/Ex ia I Ma, suitable for detection in Zone 0, Zone 1 and coal mine area

Protection level: IP66/IP68

Interface display: gas name, concentration unit, measurement value, electricity

Operating temperature: -20℃ ~ 50℃

Working humidity: 0-95%RH (non-condensing)

Machine warranty: 1 year